Company logo
Installation and Operating InstructionsSearchTable of contentsHome
 
 
Icons beside the implement image
 
Functions
 
Icon
Meaning
 SY_JR3_SECTION-Control ein_1
Sections are switched via SECTION-Control.
 SY_JR3_SECTION-Control aus
The SECTION-Control application has closed all sections.
Examples for the cause:
The sprayer is outside of the field boundary or in an area that has already been worked
Sprayer on the headland
Other causes are also possible.
 SY_JR3_Beacon
Beacon is switched on.
 SY_JR3_Licht an
The working lights are switched on.
 SY_Düsenbeleuchtung
Nozzle lighting is switched on.
 SY_JR3_Rührwerk Pause (flashing)
Stirrer has been stopped. Cause: Fill level is too low.
 SY_JR3_Rührwerk Pause (not flashing)
Stirrer has been stopped. Cause: Stopped by the driver.
 SY_JR3_Rührwerk_tank voll
Stirrer is working.
 SY_JR3_Frischwasser in Haupttank
Fresh water is being filled into the main tank.
 SY_Frischwassertransfer
Fresh water is being transferred.
 SY_Tankinnenreinigung
Tank internal cleaning is activated.
 SY_Ringleitung
Ring line function is activated.
 SY_JR3_Gebläse_links
Left fan switched on.
 SY_JR3_Gebläse_Mitte
Middle fan switched on.
 SY_JR3_Gebläse_rechts
Right fan switched on.
 SY_Hauptventil
Main valve is open (only appears if the main valve was switched on manually).
 SY_Druckluftkompressor_ein
Air compressor switched on.
 SY_Einspültrichter_heben
Mixing hopper is being lifted.
 SY_Einspültrichter_senken
Mixing hopper is being lowered.
 SY_Gestängehöhensensor
Boom height sensor activated.
If a boom height sensor is not switched (insufficient height of the boom), the air cushions and fan cannot be operated.
 SY_Ölstand
The oil level is too low.
 SY_Fahrwerk
The chassis settings are activated.
 SY_Verschiebeachse ausfahren
Sliding axle is being extended.
 SY_Verschiebeachse einfahren
Sliding axle is being retracted.
 SY_Maschine nach links neigen
The implement is being sloped to the left.
 SY_Maschine nach rechts neigen
The implement is being sloped to the right.
 SY_Produkt
Currently selected product. The currently selected product is identified with a number or a name.
 SY_Auto_Folding_Ein
Automatic folding is switched on. The automatic sequence is currently active.
 SY_Auto_Folding_Aus
Automatic folding is switched off. The automatic sequence is currently inactive.
 SY_Auto_Folding_lo_lu
In the automatic sequence, the next step is to fold on the left, and the step after that is to unfold on the left.
 SY_Auto_Folding_ro_run
In the automatic sequence, the next step is to fold on the right, and the step after that is to unfold on the right.
 SY_Auto_Folding_lu_ron
In the automatic sequence, the next step is to unfold on the right, and the step after that is to fold on the right.
 SY_Auto_Folding_ru_lo
In the automatic sequence, the next step is to unfold on the left, and the step after that is to fold on the left.
 SY_Auto_Folding_lro
In the automatic sequence, the next step is to fold on the left and right, and the step after that is to unfold on the left and right.
 SY_Auto_Folding_lru
In the automatic sequence, the next step is to unfold on the left and right, and the step after that is to fold on the left and right.
 SY_Wetterstation_Alarm
No connection to the weather station.
 SY_Zusatzfunktion_A
Additional function A is activated.
 SY_Zusatzfunktion_B
Additional function B is activated.
 SY_Zusatzfunktion_C
Additional function C is activated.
 SY_Zusatzfunktion_D
Additional function D is activated.
 
Counters
 
Icon
Meaning
 SY_JR3_Liter pro Stunde
Output in litres per minute
 SY_JR3_Hektar pro Stunde
Area output per hour
 SY_JR3_Tankfüllstand
Tank fill level
 SY_JR3_Liter pro Stunde_Ausrufezeichen
The output per minute measured by the flow meter is too low compared to the output calculated by the pressure sensor.
Fan speed
Pump speed
Can also be used to indicate whether a pump is switched on or off.