MULTI-Device
The machine is equipped with several implements and several job computers. Each of these job computers controls at least one metering unit.
Possible methods, depending on the type of spreading/application:
- ▪
- Method 1: Multiple prescription maps are used simultaneously. Each prescription map contains rate specifications for a specific implement and its metering units.
- ▪
- Method 2: A prescription map is used for one implement. The other implement was already given a fixed target rate in the job computer application or receives this fixed target rate from the ISOBUS-TC application.
With this machine type, please ensure that the correct sequence is set in the list of connections in the ISOBUS-TC application. You can find out how to change the list of connections in the ISOBUS-TC instructions.