Alarm messages
Text of alarm message | Meaning |
Nozzle was already calibrated. | The selected nozzle has already been calibrated. |
Nozzle was not calibrated. | The selected nozzle has not been calibrated yet. |
The pressure is too high. | The pressure measured by the pressure sensor is higher than the set parameter: “Max. pressure”. |
The pressure is too low. | The pressure measured by the pressure sensor is lower than the set parameter: “Min. pressure”. |
Angle sensor of the left wing is outside of the calibrated range. | The sensor value of the left wing is outside of the calibrated range. |
Angle sensor of the right wing is outside of the calibrated range. | The sensor value of the right wing is outside of the calibrated range. |
Height sensor of the left wing is outside of the calibrated range. | The sensor value of the left height sensor is outside of the calibrated range. |
Height sensor of the centre wing is outside of the calibrated range. | The sensor value of the centre height sensor is outside of the calibrated range. |
Height sensor of the right wing is outside of the calibrated range. | The sensor value of the right height sensor is outside of the calibrated range. |
Defective height angle sensor. | The angle sensor for the height is defective. |
Sensor is outside of the permissible range. | The sensor value is outside of the permissible range. |
To display the sprayer on another terminal, switch it off and restart it. To cancel, acknowledge this alarm. | If two terminals are connected, the application can be permanently assigned to one terminal. |
Target rate out of reach. | The defined target rate cannot be reached for various reasons. |
The pump is too fast. | The rotational speed of the pump is too high. |
The pump is too slow. | The rotational speed of the pump is too low. |
Pump oil level. | The oil level of the pump is too low. |
Oil level is too low | The oil level is too low. |
Boom folding forbidden: The speed is too high. | Folding is forbidden because the speed is too high. |
Not an ME terminal! A license is required to use SECTION-Control. | The SECTION-Control license is missing. |
Spraying is not possible! | Spraying is not possible for various reasons. |
Another function is active: Starting is not possible! | There is an interaction with another function. For this reason, starting is not possible. |
Fan is rotating too fast. | The fan speed is too high. |
Enter the service password to continue. | A password is required. |
To change the value, enter the user password. | A password is required. |
Enter the user password to continue. | A password is required. |
Forbidden: Function is not defined | The set constellation is forbidden by the application. |
Auto-folding AB mode: Error in one step. | There is a conflict between the set step and the AB hydraulic system. |
Auto-folding A calibration is missing. | A calibration of the sensor is missing. |
Auto-folding sensor is outside of the permissible range. | The sensor value is outside of the calibrated range. |
Auto-folding speed is too high. | The driving speed is too high to use automatic folding. |
Faulty configuration. | An error was detected in the configuration. |
The speed is too high. | The forward speed is too high. |
The configuration file was incomplete: You have used a configuration tool that is not up to date. | The utilised configuration tool version is no longer up to date. |
The tank is empty, the pump has been stopped. | The fill level of the tank is below the limit at which the pump is automatically switched off. |
Tank level sensor defective. | The fill level cannot be determined due to a sensor error. |
Check the geometry data. | The entered geometry is being verified. |
Pressure sensor defective. | The pressure cannot be determined due to a sensor error. |
ISB server defective. | An error was detected on the ISB server. |
RPM too high. | The rotational speed is too high. |
There is a difference in the selected range of side numbers. | The application checks the settings for the sides and found a difference in the sides. |
Side: Wrong configuration. | The entered side configuration is faulty. |
Actuator configuration is faulty. One actuator was used for several sections. | An actuator can always only be used for one section. |
Functions are stopped because the boom is not at the specified height. | A sufficient height of the boom was not detected. For this reason, the corresponding function was stopped. |
Function forbidden because the boom is not at the specified height | A sufficient height of the boom was not detected. For this reason, the corresponding function cannot be executed. |
Product 1 cannot be renamed. | The ClearWater product cannot be renamed. |
Product factor: Value outside of the permissible range. | The entered factor is not permitted. |
Communication with the weather station is disturbed. | The communication with the weather station is disturbed. |
Defective flap motor. | The motor is defective. |