Installation and Operating InstructionsSearchTable of contentsHome
 
 
Changing the display of areas on the terminal
 
You can make different settings to change the display of the areas on the terminal, e.g. for the TRACK-Leader application.
 
 
 
Procedure
 
 
 
1.
On the work screen, press:
 FS_JR3_Einstellungn-Menü >  FS_JR3_Zurück und Weiter >  FS_JR3_Zurück und Weiter >  FS_JR3_Zurück und Weiter >  FS_JR3_Trägheitszeiten
2.
Configure the “Zero target rate areas” parameter. The available configuration options can be found in the table.
3.
As an option, you can activate the “Record section spraying areas” parameter if you want TRACK-Leader to mark the sections as switched off as soon as all of the spraying areas are switched off.
 
 
Sections off
Applied on the map
Function
deactivated
---
The sections are not closed when the application rate is 0 l/ha.
Everything is recorded in the process.
activated
deactivated
The sections are closed when the application rate is 0 l/ha.
Only the applied areas are recorded.
activated
activated
The sections are closed when the application rate is 0 l/ha.
Both the applied areas and areas where nothing was applied will be recorded.
This is the standard setting when using SECTION-Control.