“Regulation Factor” parameter
In Automatic mode, the spray pressure of the nozzles is adapted to the current speed of the sprayer. The adjustment should ensure that the volume of spray liquid that is applied is exactly what you defined in the target rate. The regulation factor plays a decisive role here.
The regulation factor adjusts the reaction speed of the regulation:
- ▪
- The higher the regulation factor, the faster the spray pressure is adjusted.
- ▪
- The lower the regulation factor, the more slowly the spray pressure is adjusted.
When setting the regulation factor, you can pay attention to the following:
- ▪
- If, during movement at constant speed, the current application volume jumps around the target value, you need to reduce the regulation factor.
- ▪
- If, when speed is changing, the application volume does not adjust to the rate quickly enough, you need to increase the regulation factor.