Company logo
Service ManualSearchTable of contentsHome
 
 
Icons beside the implement image
 
Functions
 
Icon
Meaning
 SY_JR3_SECTION-Control ein_1
Sections are switched via SECTION-Control.
 SY_JR3_SECTION-Control aus
The SECTION-Control application has closed all sections.
Examples for the cause:
The sprayer is outside of the field boundary or in an area that has already been worked
Sprayer on the headland
Other causes are also possible.
 SY_JR3_Beacon
Beacon is switched on.
 SY_JR3_Licht an
The working lights are switched on.
 SY_Düsenbeleuchtung
Nozzle lighting is switched on.
 SY_JR3_Rührwerk Pause (flashing)
Stirrer has been stopped. Cause: Fill level is too low.
 SY_JR3_Rührwerk Pause (not flashing)
Stirrer has been stopped. Cause: Stopped by the driver.
 SY_JR3_Rührwerk_tank voll
Stirrer is working.
 SY_JR3_Frischwasser in Haupttank
Fresh water is being filled into the main tank.
 SY_Frischwassertransfer
Fresh water is being transferred.
 SY_Tankinnenreinigung
Tank internal cleaning is activated.
Low-pressure cleaner is being used.
High-pressure cleaner is being used.
The ring line is being rinsed.
 SY_Einspültrichter_heben
Mixing hopper is being lifted.
 SY_Einspültrichter_senken
Mixing hopper is being lowered.
Nozzles used in Vario mode.
Nozzles used in Select mode.
Nozzle cleaning activated.
Intended drop size with Airtec or in Vario mode.
 SY_JR3_Pumpe läuft -blau
Pump switched on.
 SY_JR3_Pumpe pausiert
Pump switched off.
 SY_JR3_Gebläse_ein
Fan switched on.
 SY_JR3_Gebläse aus
Fan switched off.
Permanent tank internal cleaning is activated.
Filter rinsing is activated.
Filter rinsing is activated and being used.
Compressed air rinsing is being used.
The support leg is being lowered.
The support leg is being raised.
 SY_Direkteinspeisung_aktiv
The corresponding unit of the Raven injection system is active.
 SY_Direkteinspeisung_aus
The corresponding unit of the Raven injection system is deactivated.
 SY_Direkteinspeisung_Fehler
The corresponding unit of the Raven injection system is not connected or not ready for operation.
CURVE-Control is activated.
 
Airtec icons
Icon
Meaning
Current air pressure
System is increasing the air pressure.
System is reducing the air pressure.
Air compressor is off.
Air compressor is on.
Manual mode is activated. The number indicates the drop size.
Drop size (automatic mode activated).
 
 
Counters and sensors
 
Icon
Meaning
 SY_JR3_Windmesser
Wind strength
 SY_JR3_Liter pro Stunde
Output in litres per minute
 SY_JR3_Hektar pro Stunde
Area output per hour
 SY_JR3_Liter pro Stunde_Ausrufezeichen
The output per minute measured by the flow meter is too low compared to the output calculated by the pressure sensor.
Fan speed
Pump speed
Can also be used to indicate whether a pump is switched on or off.