Alarm messages
 
Alarm message overview
Alarm text
Possible cause
Remedial measure
Pressure is too high.
The pressure in the tank is too high.
Set the optimal pressure.
Pressure is too low.
The pressure in the tank is too low.
Set the optimal pressure.
The fill level is low.
The tank is almost empty.
Fill the tank.
The top link is unlocked. The speed is too high.
There is still pressure on the top link. This can cause problems when driving on roads.
Unlock the top link or put it in float position.
In order to use this function, set the sequence to manual.
The automatic application or filling is activated.
Set the application or filling to manual.
Speed is too low.
A minimum speed is required for the function you want to perform.
Increase the speed.
Oil filter pressure is too high.
Overpressure in the oil filter.
Check the oil filter. If necessary, clean or replace the oil filter.
Maximum weight is reached. Check whether driving on roads is allowed.
The maximum weight for driving on roads is exceeded.
Observe the permissible total weight.
Maximum weight is reached. The front axle has been lowered.
The maximum weight for driving on roads is exceeded.
Check whether the permissible total weight can be observed with the axle lowered.
Target Rate is out of reach.
The control system is not capable of maintaining the target rate.
Drive at a constant speed or control the target rate manually.
Application pump: Rotational speed is too low.
The rotational speed of the pump is too low.
Increase the rotational speed.
Application pump: Rotational speed is too high.
The rotational speed of the pump is too high.
Reduce the rotational speed.
The application pump is blocked.
The pump is blocked or switched off.
Check the pump
Overpressure in divider.
The divider is clogged.
Remove the obstruction.
External operating device active. Before taking over the controls, check the danger area.
The implement is operated externally.
Check the danger area before operating other functions.
Not in transport position
Moving parts are not in transport position.
Put the moving parts into transport position.
Maximum speed exceeded.
The permissible maximum speed for the steering system has been exceeded.
Observe the permissible maximum speed for the steering system.
The speed is too high.
The driving speed for this function is too high.
Reduce the driving speed.
The speed is too low.
The driving speed for this function is too low.
Increase the driving speed.
Pressure is not within set range.
The pressure is not in the defined range.
Check the pressure and set it to the defined value.
Fold/Unfold is forbidden at this speed.
The driving speed is too high for folding/unfolding.
Come to a stop or reduce the speed for folding/unfolding.
Overpressure in chopper.
The chopper is clogged.
Remove the obstruction.
Gear: Rotational speed is too high.
The gearbox rotational speed is too high.
Reduce the rotational speed.
Angle sensor of first element is faulty or outside of measurement range.
The sensor is faulty or outside of the measurement range.
Check the sensor and replace it if necessary.
Angle sensor of second element is faulty or outside of measurement range.
The sensor is faulty or outside of the measurement range.
Check the sensor and replace it if necessary.
Angle sensor of third element is faulty or outside of measurement range.
The sensor is faulty or outside of the measurement range.
Check the sensor and replace it if necessary.
Angle sensor of rotating arm is faulty or outside of measurement range.
The sensor is faulty or outside of the measurement range.
Check the sensor and replace it if necessary.
Function is disabled at current speed.
The driving speed is too high for this function.
Reduce the driving speed.
Mounted implement not in transport position.
The mounted implement is not in transport position.
Put the mounted implement into transport position.
Faulty configuration.
The configuration does not correspond to the software.
Contact Customer Service.
To activate this function, restart the job computer.
The function requires a restart.
Restart the system.
The configuration is being transferred.
The configuration is being transferred to other job computers.
Wait until the configuration is completely transferred. Do not disconnect the job computer from the power source.
Tank is almost full.
The fill level sensor detects that the tank is almost full.
Observe the rest of the filling procedure.
Left-hand sensor is disabled.
The left-hand sensor is disabled.
Check the sensor and activate it.
Right-hand sensor is disabled.
The right-hand sensor is disabled.
Check the sensor and activate it.
The left-right valve is disabled.
The left-right valve is disabled.
Check the left-right valve and activate it.
The raise-lower valve is disabled.
The raise-lower valve is disabled.
Check the raise-lower valve and activate it.
Support leg is extended. Driving on roads is not possible.
The support leg is extended.
Retract the support leg completely when driving on roads.
You cannot activate this function while driving.
A function that only works when standing still has been activated.
Come to a stop in order to perform the function.
Function not possible, when speed is not within permissible range.
A function was activated outside of the permissible speed range.
Perform the function at the defined permissible speed.
Overpressure in top link
The pressure in the top link is too high.
Set the optimal pressure.
Tyre pressure is too low.
The pressure in the tyres is too low.
Set the optimal pressure.
Tyre pressure is too high.
The pressure in the tyres is too high.
Set the optimal pressure.
Timeout - Tyre Inflation System
The tyre inflation system cannot reach the set pressure.
Check the tyre inflation system.
The speed is too high. Steering system is deactivated.
The permissible maximum speed for the steering system is too high.
Observe the permissible maximum speed for the steering system.
Error. Steering system is deactivated.
Error message from the steering system.
Restart the system. If the error persists, contact Customer Service.
The mounted implement is not folded. The speed is too high.
The speed is too high for folding the mounted implement.
Reduce the speed and then fold the mounted implement.
The speed is too high. The support wheel is lowered.
The speed is too high.
Reduce the speed.
Overpressure in support wheel
The pressure in the support wheel is too high.
Set the optimal pressure.
The support wheel may not be operated. The speed is too high.
The speed is too high.
Reduce the speed.
Tyre temperature is too high.
The tyre temperature is too high.
The tyre temperature is too high.
Error – Raise the chassis. Function not possible.
The chassis cannot be raised.
Check the hydraulic system and mechanics of the chassis.
Error - Angle sensor
There is a measuring error on the angle sensor.
Check the angle sensor.
Error - Pressure sensor
There is a measuring error on the pressure sensor.
Check the pressure sensor.
Error - Control valve
There is a measuring error on the control sensor.
Check the control valve.
Error - System
There is a system error.
Check the system.
Value too big for the display.
A value cannot be displayed.
Check the settings for the units.
Hydraulic axle drive – PTO shaft speed is too low.
The rotational speed of the PTO shaft is too low.
I Increase the rotational speed of the PTO shaft.
Hydraulic axle drive – Oil pressure is too low.
The oil pressure is too low.
Increase the oil pressure.
Hydraulic axle drive – Drive speed is too high.
The drive speed of the hydraulic axle drive is too high.
Reduce the speed of the hydraulic axle drive.
Hydraulic axle drive (expert) – Activation is impossible.
Activation of the hydraulic axle drive is impossible.
Check whether the system is connected to the power supply.
Hydraulic axle drive (expert) – Incorrect change of the driving direction detected.
The driving direction was not recognised by the ISOBUS.
Check the driving direction settings.
The drawbar angle sensor is not correctly installed.
The drawbar angle sensor is not correctly installed.
Correctly install the angle sensor.
Calibration required.
The calibration is faulty.
Calibration is required.
Defective drawbar angle sensor.
The drawbar angle sensor is defective.
Replace the angle sensor.
Concentration is too low for regulation.
The concentration of the slurry is too low for regulation.
Increase the concentration.
MUT sensor is not connected.
The job computer cannot establish a connection to the MUT sensor.
Check the wiring.
License is not activated.
The licence for the selected function (e.g. MUT sensor) is not activated.
Activate the licence.