Adjusting the target rate during operation
 
You can amend the target rate while working.
 
 
 
Path
 
 
 
This is how you reach the screen with this function:
 
 
 FS_Sollwert_einstellen > ( FS_weiter_zurück)
 
 
 
Controls
 
 
 
Use the following function keys to operate the function:
 
 
Function icon
Meaning
Restores the target rate back to 100%.
Stops or starts the application.
Reduces the target rate by 10%.
Increases the target rate by 10%.
Switches between automatic and manual target rate regulation.
Automatic: The entered target rate from the “Target Rate” parameter is used.
Manual: You are working without a pre-set target rate.
Switches between automatic and manual sequence.
 
 
 
Procedure
 
 
 
1.
 FS_Sollwert_automatisch_manuell - Switch to automatic target rate control.
The following icon appears in Area 1:  SY_Sollwert_automatischer_Modus
2.
 FS_Sollwert_100,  FS_Sollwert_-10 or  FS_Sollwert_+10 - Change the target rate.
In Area 1, the change and then the new target rate is shown:
 SY_Sollwert_vor SY_Sollwert_während SY_Sollwert_nach
The job computer regulates the application according to the new target rate.