Assigning target rates
Procedure
Assigning target rates
- 1.
- Tap “Target rates”.
- ⇨
- A list of target rates and prescription maps appears.
- ⇨
- In the list, you now see the identifications of the prescription maps stored in the field data.
- ⇨
- Target rates that have not yet been assigned to a metering unit are marked with the following icon:

- 2.
- You now have two options:
- 3.
- Option a: If the machine only spreads/applies one product, exit this screen with
. In this case, the prescription map will not be assigned to a metering unit. All metering units then automatically use the same prescription map. The configuration is now complete.
- 4.
- Option b: If the machine spreads/applies different products and the task therefore contains multiple prescription maps, you must assign them to the metering units. Proceed with the following steps.
- 5.
- Tap the top line.
- ⇨
- A form for entering the target rate appears. The lines “Quantity”, “Unit” and “Product” contain values from the prescription map.
- 6.
- Tap “Implement element”.
- 7.
- Select the metering unit that should work with the prescription map.
- ⇨
- You have assigned a prescription map to a metering unit.
- 9.
- Repeat the procedure for all prescription maps in the list.
- ⇨
- You have started a task with a prescription map.
- ⇨
- When you now drive to the field and activate the machine, the target rate matching the GPS position will be transmitted to the ISOBUS job computer.