Troubleshooting
Error message text | Possible cause | Possible error correction |
Device allocation is not set. | There is more than one terminal in the tractor cab and the “Prefer internal Tractor-ECU” parameter is deactivated. | Activate the parameter and enter the tractor geometry on the ME terminal. |
The connection between the Tractor-ECU and ISOBUS-TC has been deactivated. | Activate the “Connection with ISOBUS-TC?” parameter in the Tractor-ECU application. | |
The system has detected several job computers on the ISOBUS and cannot automatically define their arrangement. | Define the list of connections manually. | |
Error: No job computer device description has been received. | The job computer has a faulty device description. | You cannot use ISOBUS-TC with this job computer. It will only be possible when the job computer software delivers the device description in a proper format. If necessary, change the “Validation of the device description” parameter. |
File error: Wrong version of the task data! Work data is damaged. Copy the damaged data and resume work with new data? | The taskdata.xml file is damaged or cannot be read for another reason. | The taskdata.xml file must be removed from the SD card. To do so, insert a USB memory device and tap “Logout”. Then insert a USB memory device with functioning data. |