Alarm messages
 
Overview of the alarm messages
Alarm text
Possible cause
Remedial measure
Metering drive is stationary.
The current speed of the metering drive is lower than the minimum speed.
Stop immediately!
Remediate the cause.
The metering drive is rotating too fast.
You are driving too fast. The metering drive cannot work reliably at the current speed.
Drive more slowly or install a larger metering roll.
Metering drive cannot maintain target rate.
You are driving too fast or too slow. It is not possible to reach the target rate at the current speed.
Drive more slowly or faster, so that the job computer can control the target rate.
Metering drive regulation range exceeded.
The current speed of the metering drive is higher or lower than the set speed.
Drive more slowly or faster or install a larger metering roll.
Metering shaft is stationary.
The revolution sensor on the metering shaft does not register any movement of the metering shaft.
Stop immediately!
Remediate the cause.
Fan is rotating too slowly.
The current fan speed is lower than the value for the "Min. Rotational Speed" parameter.
Increase the fan speed or change the "Min. Rotational Speed" parameter for the fan.
Fan is rotating too fast.
The current fan speed is higher than the value of the "Max. Rotational Speed" parameter.
Decrease the fan speed or change the "Max. Rotational Speed" parameter for the fan.
Pressure is too high.
The pressure of a linear sensor exceeds the value for the "Maximum Value" parameter.
Reduce the pressure or change the "Maximum Value" parameter.
Pressure is too low.
The pressure of a linear sensor is below the value for the "Minimum Value" parameter.
Increase the pressure or change the "Minimum Value" parameter.
Hopper is low.
There is not enough seed or fertilizer in the hopper.
Fill the hopper.
Hopper is empty.
There is no more seed or fertilizer in the hopper.
Fill the hopper.
Error in blockage system.
An error has occurred in the blockage system.
Check the blockage system.
Seed flow detected.
Seed flow has occurred in a tramline.
Check the tramline control.
No seed flow detected.
The blockage system has not detected any seed flow.
Check the blockage system.
Input is too high.
The entered value is too high.
Enter a lower value.
Input is too low.
The entered value is too low.
Enter a higher value.
Charger fault.
There is a malfunction in the alternator of the charger.
Check the alternator of the charger.
The metering was stopped because the working position was not reached. Raise the implement.
The implement is not in working position.
Raise the implement.
Error with the initialisation of the Control Layer configuration.
There was an error in the Control Layer configuration.
Check the configuration.
Right half width is not activated.
The right half width is shut off.
Activate the right half width.
Right half width is not shut off.
The right section is activated.
Shut off the right half width.
Procedure is not allowed while a task is activated in the ISOBUS-TC application.
A task is activated in the ISOBUS-TC application.
Deactivate the task.
Seed flow detected in a row that is switched off.
The row is defective.
Check the row.
Speed signal from CAN bus has been lost.
The cable was disconnected.
Check the cable connection.
Error with the reading or writing of data to the flash memory or EEPROM.
An error has occurred while the job computer was starting.
Restart the job computer.
System has been stopped. Reboot required.
The connection to a slave job computer has been interrupted.
A download manager has been activated.
Reboot the job computer.