Alarm messages
Overview of the alarm messages
Alarm text | Possible cause | Remedial measure |
Metering drive is stationary. | The current speed of the metering drive is lower than the minimum speed. | Stop immediately! Remediate the cause. |
The metering drive is rotating too fast. | You are driving too fast. The metering drive cannot work reliably at the current speed. | Drive more slowly or install a larger metering roll. |
Metering drive cannot maintain target rate. | You are driving too fast or too slow. It is not possible to reach the target rate at the current speed. | Drive more slowly or faster, so that the job computer can control the target rate. |
Metering drive regulation range exceeded. | The current speed of the metering drive is higher or lower than the set speed. | Drive more slowly or faster or install a larger metering roll. |
Metering shaft is stationary. | The revolution sensor on the metering shaft does not register any movement of the metering shaft. | Stop immediately! Remediate the cause. |
Fan is rotating too slowly. | The current fan speed is lower than the value for the "Min. Rotational Speed" parameter. | Increase the fan speed or change the "Min. Rotational Speed" parameter for the fan. |
Fan is rotating too fast. | The current fan speed is higher than the value of the "Max. Rotational Speed" parameter. | Decrease the fan speed or change the "Max. Rotational Speed" parameter for the fan. |
Pressure is too high. | The pressure of a linear sensor exceeds the value for the "Maximum Value" parameter. | Reduce the pressure or change the "Maximum Value" parameter. |
Pressure is too low. | The pressure of a linear sensor is below the value for the "Minimum Value" parameter. | Increase the pressure or change the "Minimum Value" parameter. |
Hopper is low. | There is not enough seed or fertilizer in the hopper. | Fill the hopper. |
Hopper is empty. | There is no more seed or fertilizer in the hopper. | Fill the hopper. |
Error in blockage system. | An error has occurred in the blockage system. | Check the blockage system. |
Seed flow detected. | Seed flow has occurred in a tramline. | Check the tramline control. |
No seed flow detected. | The blockage system has not detected any seed flow. | Check the blockage system. |
Input is too high. | The entered value is too high. | Enter a lower value. |
Input is too low. | The entered value is too low. | Enter a higher value. |
Charger fault. | There is a malfunction in the alternator of the charger. | Check the alternator of the charger. |
The metering was stopped because the working position was not reached. Raise the implement. | The implement is not in working position. | Raise the implement. |
Error with the initialisation of the Control Layer configuration. | There was an error in the Control Layer configuration. | Check the configuration. |
Right half width is not activated. | The right half width is shut off. | Activate the right half width. |
Right half width is not shut off. | The right section is activated. | Shut off the right half width. |
Procedure is not allowed while a task is activated in the ISOBUS-TC application. | A task is activated in the ISOBUS-TC application. | Deactivate the task. |
Seed flow detected in a row that is switched off. | The row is defective. | Check the row. |
Speed signal from CAN bus has been lost. | The cable was disconnected. | Check the cable connection. |
Error with the reading or writing of data to the flash memory or EEPROM. | An error has occurred while the job computer was starting. | Restart the job computer. |
System has been stopped. Reboot required. | The connection to a slave job computer has been interrupted. A download manager has been activated. | Reboot the job computer. |